Models with two solid state antivalent outputs
Ideal for piece counting and detectionof object presence/absence in the controlled field.
Controlled heights: 150 mm … 2525 mm.
Max. length connection cables between light curtain and interface: 50 m.
Operating temperature (°C) | 0 … 55 |
Power supply (VDC) | 24 ± 20% |
Max. range (m) | 2 for models with beam spacing 5 mm 6 for models with beam spacing 25, 50, 75 mm 16 for models with beam spacing 10, 30 mm |
Height of controlled area (mm) | 140 … 2525 |
Outputs | Two solid state antivalent outputs 0 or 24V withoutthe need for programming |
Beam spacing (mm) | 5, 10, 25, 30, 50, 75 |
METRON A
0/24 VDC digital outputs
METRON B
RS 485 serial interface with programmable functions
METRON C
Antivalent solid state outputs
Models equiped with 4 solid state outputs (0/24 VDC) with programmable functions
Ideal for object recognition, quality control, detection of dimensional limit.
Programming interface: RS 232 interface on M8 3-pole connector.
Controlled heights: 150 mm … 2525 mm.
Max. length connection cables between light curtain and interface: 50 m.
Operating temperature (°C) | 0 … 55 |
Power supply (VDC) | 24 ± 20% |
Max. range (m) | 2 for models with beam spacing 5 mm 6 for models with beam spacing 25, 50, 75 mm 16 for models with beam spacing 10, 30 mm |
Height of controlled area (mm) | 140 … 2525 |
Outputs | 4 solid state outputs 0 or 24V with programmable functions. |
Beam spacing (mm) | 5, 10, 25, 30, 50, 75 |
METRON A
0/24 VDC digital outputs
METRON B
RS 485 serial interface with programmable functions
METRON C
Antivalent solid state outputs