Protection of areas with access points on multiple sides, with a considerable reduction of costs
The following rules should be taken into consideration when using deflector mirrors:
- the working distance (range) is given by the sum of the lengths of all the sides giving access to the protected area
- For each mirror used the maximum working range between the Emitter and the Receiver is reduced by 15%
- Place the mirrors in order to ensure compliance with the minimum safety distance on each side from which the danger zone can be accessed
- When light curtains and grids are working with long distance or with deflector mirrors, it is recommendable to use the LAD laser pointer for a quick and reliable alignment of the system
Input | One two-channel inputs for safety light curtains |
Safety relay outputs | 2 N.O. – 2 A 250 VAC |
Status output: | PNP – 100 mA at 24 VDC |
Response time (ms) | <= 20 |
Start/Restart command | Manual or automatic. Start/Restart selectable on terminal block |
External relay control | Yes – EDM Feedback input for extra external contactors monitoring |
Signalling | LED indication of input/output status and diagnosis |
Power supply (VDC) | 24 ± 20% |
Electrical connections | On terminal blocks |
Operating temperature (°C) | 0 … 55 |
Protection rating | IP 20 for housing – IP 2X for terminal blocks |
Fastening | On DIN rail fastening according to EN 50022-35 standard |
Dimensions h x w x d (mm) | 99 x 22,5 x 114. |
- 2006/42/EC: Machine Directive
- 2014/30/EU: Electromagnetic Compatibility Directive
- 2014/35/EU: Low Voltage Directive
- EN 61496-1:2013 (Type 4) Safety of machinery. Electro sensitive protective equipment. General requirements and tests
- EN 61496-2:2013 (Type 4) Safety of machinery. Electro-sensitive protective equipment. Particular requirements for equipment using active opto-electronic protective devices (AOPDs)
- IEC 62061 (ed. 1); am1 (SILCL 3) Safety of machinery. Functional safety of safety-related electrical, electronic and programmable electronic control systems
- ISO 13849-1:2008/AC:2009 (Cat. 4, PL e) Safety of machinery – Safety-related parts of control systems. Part 1: General principles for design
- UL (C+US) mark for USA and Canada
Recent Comments