Tip 4, SILCL3, PL e, Kat. Entegre bankacılık fonksiyonlarına sahip 4 Emniyetli Işık Perdesi
Amiral Tip 4 güvenlik ışık perdeleri ailesi, yüksek riskli endüstriyel uygulamaların çoğunun korunması için ideal bir çözümdür.
İki bariyeri ve Floating Blanking’li modellerin kademeli olarak bağlanması için Master / Slave modelleri de dahil olmak üzere ürün yelpazesinin genişliği.
Uzun Menzilli modeller 2, 3 ve 4 ile kirişlerin maks. 60 m, İkili Model Kirişler maks. 80 m.
Safety level | Type 4 according to IEC 61496-1; IEC 61496-2 SILCL 3 according to IEC 62061 PL e -Cat. 4 according to ISO 13849-1 |
Protected heights (m) | 160 … 1810 (for some resolution up to 2160 |
Response time (ms) | 6 … 27 |
Safety outputs | 2 PNP – 500 mA at 24 VDC with short-circuit, overload, polarity reversal protection |
Signalling | Seven-segment display LEDs for light curtain’s status and diagnostic On the receivers of all models, a yellow LED turns ON when the received beam signal intensity is weak |
Power supply (VDC) | 24 ± 20% |
Max. cable length (m) | 100 |
Operating temperature (°C) | 0 … 55 |
Protection rate | IP 65 |
Fastening modes | Back slot, side slot or to the top and lower end with swivel brackets |
Cross section (mm) | 35 x 45 |
- 2006/42/EC: Machine Directive
- 2014/30/EU: Electromagnetic Compatibility Directive
- 2014/35/EU: Low Voltage Directive
- IEC 61496-1 (ed. 3) Safety of machinery. Electro sensitive protective equipment. General requirements and tests
- IEC 61496-2 (ed. 3) Safety of machinery. Electro-sensitive protective equipment. Particular requirements for equipment using active opto-electronic protective devices (AOPDs)
- IEC 62061 (ed. 1) (SILCL 3) Safety of machinery. Functional safety of safety-related electrical, electronic and programmable electronic control systems
- ISO 13849-1:2006 (Cat. 4, PL e)Safety of machinery: safety-related parts of control systems. Part 1: General principles for design
- EN 50178:1997 Electronic equipment for use in power installations
- EN 55022:2010 Information Technology Equipment. Radio Disturbance Characteristics. Limits and Methods of Measurement
- UL (C+US) mark for USA and Canada
- Marchio TS per Taiwan
- ANSI / UL 1998: Safety Software in Programmable Components