Type 2 control unit for Ilion and Ulisse photocells
Control unit for safety photocells Ilion and Ulisse, which can be combined to form a Type 2 safety system.
- Up to 4 photocells may be connected
- Guided-contact safety relays
- Start/Restart interlock
- EDM Feedback input for external contactors monitoring
- Self test every 5 seconds
Number of photocells | 1 … 4 |
Safety relay outputs | 2 N.O. – 2 A 250 VAC |
Status output | PNP – 100 mA at 24 VDC |
Response time (ms) | <= 30 |
Start/restart command | Manual or automatic. Start/Restart selectable on terminal block |
External Device Monitoring | Yes – EDM Feedback input for external contactors monitoring |
Signalling | LED indication of input/output status and diagnosis |
Power supply (VDC) | 24 ± 20% |
Electrical connections | On terminal block |
Operating temperature (°C) | 0 … 55 |
Protection rating | IP 20 for housing – IP 2X for terminal block |
Fastening | On DIN rail fastening according to EN 50022-35 standard |
Dimensions h x w x d (mm) | 99 x 22,5 x 114 |
- 2006/42/EC: Machine Directive
- 2014/30/EU: Electromagnetic Compatibility Directive
- 2014/35/EU: Low Voltage Directive
- EN 61496-1:2013 Safety of machinery. Electro sensitive protective equipment. General requirements and tests
- IEC 62061 (ed.1) (SILCL 1) Safety of machinery. Functional safety of safety-related electrical, electronic and programmable electronic control systems
- EN ISO 13849-1:2008 (Cat. 2, PL c) Safety of machinery. Safety-related parts of control systems. Part 1: General principles for design
- EN 50178:1997 Electronic equipment for use in power installations
- EN 55022:2010 Information Technology Equipment. Radio Disturbance Characteristics. Limits and Methods of Measurement
- UL (C+US) mark for USA and Canada