Models equiped with two analog outputs 4/20 mA with programmable functions and two programmable digital outputs
Ideal for object measurement and detection of dimensional limit.
Controlled heights: 150 mm … 3000 mm (150 mm … 1500 mm – models with beams spacing 5 mm).
Programming interface: USB interface on M5 4-pole connector.
Max. length connection cables between light curtain and interface: 100 m.
Operating temperature (°C) | -10 … 55 |
Power supply (VDC) | 24 ± 20% |
Max. range (m) | 2,5 – models with beams spacing 5 mm 6 – special models with beams spacing 25, 50, 75 mmfor automatic warehouses 10 – models with beams spacing 10, 30 mm 18 – models with beams spacing 25, 50, 75 mm |
Height of controlled area (mm) | 150 … 3000 – for models with 10, 25, 30, 50, 75 mm beams spacing 150 … 1500 – for models with beams spacing 5 mm |
Outputs | Two analog outputs (0 … 20 mA) with programmable functions + Two solid state 0 or 24 V programmable digital outputs |
Beam spacing (mm) | 5, 10, 25, 30, 50, 75 |
MICRON AV
0/10 VDC analog outputs
MICRON AC
4/20 mA analog outputs
MICRON B
RS 485 serial interface with programmable functions
MICRON C
Antivalent solid state outputs
MICRON M5
Multibeams photocells
Recent Comments