Safety light curtain with integrated muting functions
The new SAFEGATE type 4 range of safety light curtains is the ideal solution for the protection of a vast number of high-risk industrial applications, in particular those requiring a highlevel of integration of the muting functions.
SAFEGATE guarantees the integration of the muting sensors that can be connected directly to the safety light curtain.
- Hardware configurable models (SM/SMO) allow configuration of the muting logic and functional parameters via the main connector wiring
- Programmable models (SMPO) functional parameters configuration is managed instead via Safegate Configuration Software (SCS)
Safety level | Type 4 according to EN 61496-1; IEC 61496-2 SIL 3 according to IEC 61508 SILCL 3 according to IEC 62061 PL e Cat. 4 according to EN ISO 13849-1 |
|
Protected heights | 300 mm … 2200 mm | |
Risolution | 30 and 40 mm – 2, 3 and 4 beams | |
Versions | Emitter/receiver | |
Transreceiver version | Passive retro-reflector elements | |
Safety functions | Static outputs EDM Start/Restart Interlock |
|
Cross-section dimensions | 55 x 50 mm | |
Protection rating | IP 65 e IP 67 | |
Operating temperature (°C) | -30 … 55 (without condensing) | |
Muting lamp | Integratd (optional) |
- 2006/42/EC: Machine Directive
- 2014/30/EU: Electromagnetic Compatibility Directive
- 2014/35/EU: Low Voltage Directive
- EN 61496-1:2013 (Type 4) Safety of machinery. Electro-sensitive protective equipment. General requirements and tests
- EN 61496-2:2013 (Type 4) Safety of machinery. Electro-sensitive protective equipment. Particular requirements for equipment using active opto-electronic protective devices (AOPDs)
- EN 61508-1:2010 (SIL 3) Functional safetyof electrical/electronic programmable electronic safety related systems. General requirements
- EN 61508-2:2010 (SIL 3) Functional safety of electrical/electronic/programmable electronic safety related systems. Requirements for electrical/electronic/programmable electronic safety-related systems
- EN 61508-3:2010 (SIL 3) Functional safety of electrical/electronic programmable electronic safety related systems. Software requirements
- EN 61508-4:2010 (SIL 3) Functional safety of electrical/electronic programmable electronic safety related systems. Definitions and abbreviations
- EN 62061:2005/A2:2015 (SILCL 3) Safety of machinery. Functional safety of safety-related electrical, electronic and programmable electronic control systems
- EN ISO 13849-1:2015 (Cat. 4, PL e) Safety of machinery. Safety-related parts of control systems. Part 1: General principles for design
- UL (C+US) mark for USA and Canada
- ANSI / UL 1998: Safety Software in Programmable Components
- Palletizers
- Robotized areas
- Assembly lines
- Automatic industrial warehouses
- Areas through which AGV automatically guided vehicles pass
- Access control
- Cutting machines
- Robot-palletisers
- Automatic punching machines
- Shear lines
Muting applications
- “L” Logic Crossed beams
Suitable solution for any applications of pallet exit - “L” Logic Parallel beams
Suitable solution for transparent material: glass and bottling industry of pallet exit - “T” Logic Crossed beams
Suitable solution for the most common pallet infeed/outfeed applications
Ideal solution in case of a continuous flow of pallets even without separation between the pallets - “T” Logic Parallel beams
Suitable solution for transparent material and application with presence of a pallet with reduced width or not centred with respect to the conveyor. Through the verification of the 4 sensors, allows to set infinite muting time-out
Please note: this configuration needs a separation between two consecutive pallets equal to the distance between the two external muting sensors